Shaanxi Sier Electronics Co., Ltd.

Shaanxi Sier Electronics Co., Ltd.

Manufacturer from China
Active Member
6 Years
Home / Products / Piezoresistive Differential Pressure Transmitter /

12VDC Piezoresistive Pressure Transmitter

Contact Now
Shaanxi Sier Electronics Co., Ltd.
City:baoji
Province/State:Shaanxi
Country/Region:china
Contact Person:kenny
Contact Now

12VDC Piezoresistive Pressure Transmitter

Ask Latest Price
Video Channel
Brand Name :Sier
Model Number :SPT91L
Certification :CE,RoHS
Place of Origin :China
MOQ :1piece
Price :USD60~100/Piece
Payment Terms :T/T, Western Union
Supply Ability :5000 pieces each month
Delivery Time :7
Packaging Details :Carton
Accuracy :±1%FS
Stability :≤0.5%FS / Year
Application temp. :-20~80℃
Power Supply :12-32VDC
Pressure Range :0-100kPa
Output Signal :4-20mA / RS485
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

12VDC Piezoresistive Pressure Transmitter

Low Pressure (differential) Transmitter

Features12VDC Piezoresistive Pressure Transmitter

·Industrial protection grade;

·Fully stainless steel structure;

·4-20mA, RS485, 0-5V/10V output;

Introduction

The differential pressure transmitter uses full digital smart board card, equipped with SMi full digital import chip. With high stability, dynamic measurement performance , etc. Configure high-performance microprocessor to correct for sensor nonlinearity and temperature drift, Accurate digital data transfer, field device diagnostics, remote two-way communication, etc. This transmitter has a variety of ranges to fits the needs of various of users.Widely used in metallurgy, machinery, petroleum, chemical, power stations, light industry, food, environmental protection, national defense and scientific research in various fields.

Specification

Pressure Range 0-100kPa
Accuracy ±1%FS
Power Supply 12-32VDC
Output Signal 4-20mA / RS485
Stability ≤0.5%FS / Year
Application temp. -20~80℃

Outline Construction


(Unit: mm)

12VDC Piezoresistive Pressure Transmitter

The differential pressure transmitter has two air intakes, one high-pressure air intake, marked "H" and a low-pressure air intake marked "L". During the installation process, air leakage is not allowed, and the presence of air leakage will reduce the accuracy of the measurement.

Electric Connection

Cable Connection

Wire color 2-wire(4-20mA) 4-wire(485)
Red (+V) (+V)
Yellow (-V) (-V)
Blue Null 485A
Green Null 485B

Use maintenance

USE

1. The differential pressure transmitter is small size and light weight, it can be installed directly on the measuring point when installation, pay attention to check the sealing of the pressure interface to prevent the measurement accuracy from being affected by air leakage.

2. The transmitter can enter the working state by connecting the wires as required. When measurement accuracy requirements are high, the meter should be powered on for half an hour before entering the working state.

Maintain

1. Normal use of the transmitter requires no maintenance

2. Transmitter calibration method: When the pressure is zero, first adjust the zero point, then make the pressure to the full range, verify the full scale, and repeat until the standard is reached.

3. The regular calibration of the instrument should be operated by professionals to avoid damage.

4. The instrument should be storage at 10-30℃ and the humidity at 30-80% with a clean environment when you not use it.